Total Solutions POPs Laboratories of the Future

submitted by: Chrom Solutions

Total Solutions POPs Laboratories of the Future

Tom Hall, FMS, USA

Presented at the Thermo Scientific POPs Symposium 2015 in Bremen, Germany

Development and Application of a Bench-top High Resolution and High Mass Accuracy GC/Quadrupole-Orbitrap MS

submitted by: Chrom Solutions

Development and Application of a Bench-top High Resolution and High Mass Accuracy Gas Chromatograph/Quadrupole-Orbitrap Mass Spectrometer

Amelia Peterson, University of Wisconsin, USA

Presented at the Thermo Scientific POPs Symposium 2015 in Bremen, Germany

Past, Present and Future of Orbitrap Mass Spectrometry

submitted by: Chrom Solutions

Past, Present and Future of Orbitrap Mass Spectrometry

Alexander Makarov, Thermo Fisher Scientific, Germany

Presented at the Thermo Scientific POPs Symposium 2015 in Bremen, Germany

Analysis of Dioxins in Stack Gas Emissions: Samples Collected by Continuous Sampling Devices

submitted by: Chrom Solutions

Analysis of Dioxins in Stack Gas Emissions - Samples Collected by Continuous Sampling Devices: High Content Samples, Another Issue for Mass Spectrometry

Esteban Abad, IDAEA-CSIC, Spain

Presented at the Thermo Scientific POPs Symposium 2015 in Bremen, Germany

An Analogous Technique to Dilute-and-Shoot LC-MS/MS to Improve Gas Chromatographic Performance

submitted by: Chrom Solutions

Shoot-and-Dilute GC-MS/MS: An Analogous Technique to Dilute-and-Shoot LC-MS/MS to Improve Gas Chromatographic Performance

Jack Cochran, Restek Corporation, USA

Presented at the Thermo Scientific POPs Symposium 2015 in Bremen, Germany

Levels and Trends of Legacy and Emerging POPs in the Spanish Environment

submitted by: Chrom Solutions

Levels and Trends of Legacy and Emerging POPs in the Spanish Environment

Begoña Jiménez, IQOG-CSIC, Spain

Presented at the Thermo Scientific POPs Symposium 2015 in Bremen, Germany

Determination of PCDD/Fs in Environmental Samples using Accelerated Solvent Extraction (ASE) and GC-MS/MS

submitted by: Chrom Solutions

Determination of PCDD/Fs in Environmental Samples using Accelerated Solvent Extraction (ASE) and GC-MS/MS

Fabrizio Galbiati, Thermo Fisher Scientific, Switzerland

Presented at the Thermo Scientific POPs Symposium 2015 in Bremen, Germany

Low Cost Dioxin Analysis: Simplified Manual Sample Clean-up

submitted by: Chrom Solutions

Low Cost Dioxin Analysis - Simplified Manual Sample Clean-up using Disposable Preparation Columns Combined with Thermo Scientific TSQ 8000 GC-MS/MS

David Hope, Pacific Rim Laboratories Inc., Canada

Presented at the Thermo Scientific POPs Symposium 2015 in Bremen, Germany

DFS Technology Update

submitted by: Chrom Solutions

DFS Technology Update

Heinz Mehlmann, Thermo Fisher Scientific, Germany

Presented at the Thermo Scientific POPs Symposium 2015 in Bremen, Germany

Cultures Magazine Launch Event - MWV84

submitted by: MicrobeWorld

Watch highlights from the Cultures Magazine Launch Event held on January 23, 2014 at American Society for Microbiology headquarters in Washington, D.C.

Cultures is a free, online, open-source publication available for viewing at www.asm.org/cultures.